NIDEK EC5000CXIII EXCIMER LASER

NIDEK EC5000CXIII EXCIMER LASERCompany: Nidek

Purpose: Excimer Laser

Link: http://www.nidek.com/ec5000.html

Excellent Surface Quality
An innovative scanning technology to realize a uniform ablated surface with the highest precision.

Advanced Ergonomics & User Friendly Platform
Offers small foot print yet greater versatility.

Innovative Algorithms for Optimized Laser Treatments & Surgical Outcomes

Superior Protective & Safety Mechanisms

Computerized Performance
Laser delivery parameters are automatically calculated by entering the basic data. During the ablation procedure, the computer monitors the system parameters continuously.

The system can be integrated into NAVEX Quest
NIDEK's Advanced Vision Excimer Laser System.

Advanced & Automated Magnification Controls

Faster Operation
Faster system check and mechanical alignment time.

High Speed 200Hz Eye Tracking System

Torsion Error Detector (TED)

MultiPointTM Ablation

Super Flex Scan


NAVEX Quest

NIDEK's Advanced Vision Excimer Laser System

NIDEK's Advanced Vision Excimer Laser System

Please click the picture on the right to view it in a larger size.


OCULUS PENTACAM

OCULUS PENTACAMCompany: OCULUS

Purpose:

Link: http://www.oculususa.com/prd_comp.php

Principle of Measurement
The Pentacam images the anterior segment of the eye by a rotating Scheimpflug camera measurement. This rotating process supplies pictures in three dimensions. The center of the cornea is measured very precisely because of this rotational imaging process.
The measurement process lasts less than two seconds and minute eye movements are captured and corrected simultaneously. By measuring 25,000 true elevation points, precise representation, repeatability and analysis are guaranteed. The following information on the eye is captured.

Scheimpflug Image

3-D Chamber Analysis

Corneal Topography

Pachymetry

Cataract Analysis

True Net Power

Keratometric Power Deviation

Tomography

Holladay Report
During the last ESCRS in Lisbon Oculus Optikgeräte GmbH presents the “Holladay Report” for the first time. This new program was developed together with Dr. Jack T. Holladay to improve the calculation of IOLs for patients which have undergone corneal surgery. This problem is well known and several methods have been tried to get proper k-readings for the calculation of the IOL but no method was precise enough. All those methods which have been in use so far are assumptions and approximations. The Pentacam is the first and only machine in the market which delivers the necessary values.


OCULAR COHERENCE TOMOGRAPHY [OCT]

OCULAR COHERENCE TOMOGRAPHY [OCT]Company: Zeiss Meditec

Purpose: Cross-Sectional Imaging of Retina

Optical coherence tomography (OCT) is a new, noninvasive, noncontact, transpupillary imaging technology which can image retinal structures in vivo with a resolution of 10 to 17 microns.
Cross-sectional images of the retina are produced using the optical backscattering of light in a fashion analogous to B- scan ultrasonography. The anatomic layers within the retina can be differentiated and retinal thickness can be measured.

 

IOL MASTER

IOL MASTER

Company: Zeiss Meditec

Purpose: Measurements of ocular parameters used commonly in cataract + refractive surgery

The Zeiss IOL Master is a non-contact optical device that measures the distance from the corneal vertex to the retinal pigment epithelium by partial coherence interferometry, the IOL Master is consistently accurate to within ±0.02 mm or better.

The IOL Master is the first such device to be widely used in clinical ophthalmology.

Optical biometry along the visual axis is highly accurate. Erroneous measurements are virtually eliminated. Exact measurement of the length of the ocular axis is possible even with eyes not ideally formed. High ametropia, pupil size as well as state of accommodation will not affect the accuracy of measurement. The risk of confusing right and left eye is excluded. The instrument automatically detects the right or left eye while taking the measurement.
 

 

AUTO REFRACTOR HARK 599

AUTO REFRACTOR HARK 599

Company: Zeiss Meditec

Purpose: Auto refractor/keratometer

The HARK 599 is the first full-featured
combination auto refractor/keratometer
with glare testing. Unlike other instruments,
the HARK allows for immediate patient feedback on the prescription.

Complete testing - Automatic alignment and tracking allow the instrument to follow shifts in eye movement during testing, while speeding up routine examination time, improving patient comfort level and achieving highly accurate refractions.

Automatic Keratometric readings In addition to all the features of the Automatic Refractor, the HARK 599 provides precise keratometric readings including Delta K's that are quickly and easily performed for all clinical needs.
 

 

HUMPHREY Visual Fields HFA II

HUMPHREY Visual Fields HFA II Company: Zeiss Meditec

Purpose: Eye diagnostic

The Humphrey Field Analyzer II is the recognized standard of care for early diagnosis, treatment and management of diseases resulting in visual field loss. With over 35,000 HFA systems in use around the world, the HFA is documented in hundreds of clinical trials.

Early Glaucoma Detection - Blue-Yellow perimetry has been shown to provide earlier detection of glaucomatous visual field loss

Reliable Results - Patented fixation monitoring features automatically track and align patient head and eye position, alerting the operator to patient movement away from the trial lens.
Patients appreciate the ergonomically designed instrument - that allows for maximum comfort.

 

ORBSCAN

ORBSCAN Company: Bausch + Lomb

Purpose: Corneal scanning machine used in pre-operative evaluation for laser eye surgery

Purpose: Corneal scanning machine used in pre-operative evaluation for laser eye surgery.

The Orbscan is a very special test that helps the doctors to determine if you are a candidate for LASIK. It is the only test that can show us the shape of the posterior surface of your cornea.

"The Orbscan II acquires over 9000 data points in 1.5 seconds to meticulously map the entire corneal surface (11 mm), and analyze elevation and curvature measurements on both the anterior and posterior surfaces of the cornea."
This level of analysis is absolutely impossible for a doctor to conduct without the Orbscan.

The Orbscan also gives us your corneal thickness measurement anywhere on your cornea. Corneal thickness is very important because since we changing the shape of you cornea by removing tissue we do not want to make your cornea too thin. The average cornea is 515 microns thick. Our rule is to not make your cornea total thickness not thinner than 400 microns or less than 250 microns under the flap. This is best measured with the Orbscan.

 
 
RT2100 Refractor

RT2100 Refractor Company: Various NIDEK items

Purpose: Eye Measurement

The world's first automatic computation program analyzes massive amount of measurement data and computes "the most comfortable value" for the patient.

 

 
Nikon Fundus Camera and OCULAB Imaging digital photography

Company: NIKON or RIGHT MEDICAL

Purpose: Eye Imaging

The NF-505 enables to take extremely high quality fundus photographs, yet, makes fundus examinations simple and efficient. It is designed to improve photographic reliability to make fundus examinations as easy and comfortable as possible for both the operator and the patient.

 
Nidek ARK-30 Auto refractor

Company: Nidek

Purpose: Auto refractor

 
CSO digital capture Slit Lamp SL 980 ReSeevit 5 package
Company: Costruzione Strumenti Oftalmici S.r.l. (Italy)

Purpose: Eye Imaging

The ReSeeVit™ 5.0 Slit Lamp System is an easy-to-use digital imaging system that captures anterior segment photos for documentation, diagnosis and patient education.

The ReSeeVit 4-D Mega Pixel Digital Camera is a direct digital video camera with an effective resolution of 4.0 mega pixels. Designed to interface with the ReSeeVit™ line of slit lamps, the 4-D utilizes the latest technology to capture extremely high quality images, including endothelial cells.

 
Moria M2 microkeratome
Company: MORIA France (Instrumentation and Lasik)

Purpose: LASIK

Nidek OPD ARK-9000 unit auto-refractor + topographer + wavefront analyser
 
Nidek NCT 20 non contact tonometer
 
Humphrey A-B ultrasound scan [Zeiss Meditec company]
 
Specular Microscopy – CSO UNIT
 


 